G1010 Mark II Series Oxygen Analysers

Applications

 

Air separation plants
Nitrogen purged soldering systems
Cylinder gas quality
Food packaging and storing
Purge gas monitoring
Landfill gas monitoring
Glove boxes
Workplace air monitoring
Medical monitoring

 

The oxygen analysers in the G1010 Series use galvanic cell primary elements and can measure oxygen concentrations from 100% to 0.1ppm (parts per million) in a variety of gases. The instruments are micro-processor-controlled and provide exceptional performance and versatility.

A large multi-digit, auto-ranging LCD shows the concentration and user-adjustable parameters.

Two alarm channels, user-programmable to be high, low or off, each provide one set of volt-free changeover contacts, and can be set to any concentration within the span of the instrument.

A user programmable analogue output can be set to one of several ranges. A choice of 0 to 5v or 4 to 20mA is provided at the time of ordering.

Several versions of sensor are available, enabling the analyser to operate at optimum performance in a diverse range of applications. These include a sensor suitable for operating in the presence of high concentrations of mildly acidic gases such as carbon dioxide and hydrogen sulphide.

Remote sensor versions are available that allow the separation of the control/ display module and sensor by up to several hundred metres. Depending on the distance and concentration being measured, the sensor is either connected directly to the display module or via an integral two-wire transmitter.

Because the sensor conforms to the ‘simple apparatus’ category as defined by European standard EN 50020, remote sensors may be located in a hazardous area. A suitable zener barrier or galvanic isolator must be inserted between the sensor assembly and the control/display module.

Three other analysers are derived from the G1010:  The bench-top G210 is a mains powered analyser which can be equipped with a variety of sampling systems and accessories including a pump, filter and flow control.

The wall-mounting G610 is packaged in an IP65 enclosure allowing it to be located in almost any industrial situation.

The fully portable G810 is fitted with a sample pump as standard and can operate for over 12 hours on its rechargeable battery pack. Specification sheet HPS130 gives full details

SPECIFICATION

G1010 Mark II Series Oxygen Analysers

Display

Multi-digit LCD - character height 1 2.7mm

Display ranges

E version - display range 0.01% to 100.0%. Suitable for samples containing mildly acidic gases; eg, carbon dioxide, hydrogen sulphide etc

N version - display range 100ppm to 50%

L version - display range 0.1ppm to 25%

Display resolution

 

 

0.1% from 10% to 100%

0.01% from 0.50% to 9.99%

10ppm from 500ppm to 4999ppm

1ppm from 50ppm to 499ppm

0.1ppm from 0ppm to 49.9ppm

Stability

Better than 2% of full-scale per month

Cell life

E version - up to 5 years

N and L versions - up to 2 years

Sample flow

Between 100 and 300ml/min for optimum operation. Max 1 litre/mm.

Sample temperature

 

-5 to +40°C (non condensing)

Sample connections

 

 

Inlet and outlet: captive-seal compression fittings suitable for 0.25 inch (or 6mm) o/d tube

 

Speed of response

190 - variable depending on sensor and concentration. Approximately 3s at % levels and 20s at ppm levels. The ppm figure assumes that the sensor is purged down to the ppm concentration of interest.

Analogue outputs

0 to 5V or 4 to 20mA (specify at time of order) Each user-programmable to the following spans:

   E version 0 to 100%, 0 to 25%, 0 to 5%

   N version 0 to 100%, 0 to 25%, 0 to 5%, 0 to 5000ppm, 0 to 500ppm

   Lversion 0 to 25%, 0 to 5%, 0 to 5000ppm, 0 to 500ppm, 0 to 50ppm

G1O1OTX output

 

The output span of the Tx version is fixed to any one of the

ranges given above.

Alarm outputs

 

Two alarms, each user-programmable for mode - HIGH, LOW

or OFF Hysteresis programmable from 0 to 10% of set point Volt-free changeover contacts rated at 250V r.m.s.a.c max., 3A max., max power 60W, normally energised.

Ambient temperature

 

0 to 40°C (continuous operation)

-5 to +55°C (intermittent operation)

Power supply

 

110/120V or 220/240V, 50/60Hz; 24V dc

Max power consumption 4VA

Enclosure

 

Panel-mounting glass-reinforced Noryl case to IP40. Optional

lockable transparent door to IP54 is available.

Dimensions

See drawing below

Up Next

Download a full specification (pdf)

For more information, please contact Technical Sales who would be delighted to discuss your needs

 

Cambridge Sensotec Limited
Unit 8, Royce Court
Burrel Road

St. Ives
CAMBS
PE27 3NE
ENGLAND

Tel. +44 (0)1480 462142
  Fax. +44 (0)1480 466032
mobile (07866) 624236
  sales@cambridge-sensotec.co.uk
Registered in England No. 4035592
VAT No. 745 9399 75

List of Gases we supply detectors for: oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), hydrogen sulfide (H2S), Explosive gas (% LEL), hydrogen (H2), helium (He), argon (Ar), neon (Ne), Freon, nitrogen (N2), ammonia (NH3), hydrogen chloride (HCl), hydrogen cyanide (HCN), ozone (O3) hydrogen fluoride (HF), nitric oxide (NO), nitrogen dioxide (NO2), ethylene (C2H4), chlorine (Cl2), ethylene oxide (ETO), sulfur dioxide (SO2), silane (SiH4), phosphine (PH3), arsine (ASH3), chlorine dioxide (CLO2), phosgene (COCl2), fluorine (F2), hydrazine (N2H4), volatile organic components (VOC), acetone ( CH3COCH3), acetylene (C2H2), benzene (C6H6), butane (C4H10), methane (CH4), pentane (C5H12), propane (C3H8), toluene (C7H8), xylene (C8H10), gasoline, diesel & kerosene CLICK HERE FOR SITE MAP